Pre-configured board
Preconfigured 4 × 12 TE sub-distribution board
Large single field: four rows of 12 modules. Built for bigger homes with a wallbox or heat pump.
- 4 rows
- 48 TE
| Type | Description | TE | Qty | Σ TE | Link |
|---|---|---|---|---|---|
| ENCLOSURE | Striebel & John field distribution board, surface-mounted, 1 field × 4 rows (48 TE) | 1× | Search on Amazon ↗ | ||
| MAIN_SWITCH | Hauptschalter 40A 3P | 3 | 1× | 3 | Amazon ↗ |
| SPD | ÜSS DEHN DG MP TNS 275 | 4 | 1× | 4 | Amazon ↗ |
| TERMINAL | Hauptleitungs-Abzweigklemme HLAK 25-1/2 M2 | 1 | 5× | 5 | 1× Amazon ↗ |
| RCD_FI | FI 4P Typ A 40A / 0,03A | 4 | 2× | 8 | Amazon ↗ |
| MCB | LS B16 | 1 | 14× | 14 | Amazon ↗ |
| MCB | LS B20 | 1 | 2× | 2 | Amazon ↗ |
| MAIN_SWITCH | Hauptschalter 40A 4P | 4 | 2× | 8 | Amazon ↗ |
| WIRING | Leitung H07V-K 2,5 mm² | 0.9 ~m | 1× Amazon ↗ | ||
| WIRING | Leitung H07V-K 10 mm² | 8.5 ~m | 1× Amazon ↗ | ||
| WIRING | Aderendhülse 2,5 mm² (langer Kragen) | 7 St. | 1× Amazon ↗ | ||
| WIRING | Aderendhülse 10 mm² (langer Kragen) | 33 St. | 1× Amazon ↗ | ||
| WIRING | Zwillingsaderendhülse 10 mm² (langer Kragen) | 15 St. | 1× Amazon ↗ | ||
| WIRING | Sammelschiene 3P+N (für den 4-poligen FI) | 2 St. | Amazon ↗ | ||
| Gesamt | 27× | 44 | |||
Not a shop: fuseplan.app compiles the parts on Amazon, the purchase is made on Amazon (affiliate links). Installation by a qualified electrician only. Terms & Safety
Each link opens the product page with all offers. Compare the price there and add the article to your basket yourself.
As an Amazon Associate we earn from qualifying purchases.
The ready-made configurations are examples that show what the planner can do. We give no warranty that they are correct, complete or functional. They are not designed for any specific installation. A qualified electrician must check every configuration and adapt it to the installation before it is fitted. Terms of use & safety
About this board
48 module slots on four DIN rails in one field, a step up from the standard 3 × 12 TE board for a larger single-family home or higher electrical demand.
The fourth row carries its own type-B RCD, sized for the DC fault currents an EV charger or a heat pump inverter can produce, plus a contactor for load management. Pick a brand below to price the full bill of materials.
Other sizes
Need something else? Build your own in the planner.